Evaluation of Radiation Protection Practices in a Conventional Radiography Room at RSKD Ibu dan Anak Pertiwi
DOI:
https://doi.org/10.58184/miki.v4i3.1005Keywords:
conventional radiography, compliance with regulations, personal protective equipment, qualitative evaluation, radiation protection, safety standardsAbstract
The use of ionizing radiation in diagnostic radiographic examinations poses biological risks, particularly among vulnerable groups such as pediatric patients and women of reproductive age. Therefore, the implementation of radiation safety and protection standards is an essential aspect of radiological services. This study aimed to evaluate the implementation of radiation safety protection standards in the conventional radiography examination room of the Radiology Installation at RSKD Ibu dan Anak Pertiwi. This study employed a qualitative descriptive design involving three radiographers as key informants selected through purposive sampling. Data were collected through checklist-based observations, in-depth interviews, exploratory questionnaires as supporting data, and document reviews. Data analysis was performed using source and technique triangulation. The findings revealed a gap between the implementation of radiation protection practices in the field and the requirements stipulated in BAPETEN Regulation No. 4 of 2020. The main discrepancies were identified in the limited availability of specific Personal Protective Equipment (PPE), including thyroid shields, gonadal shields, lead glasses, and lead gloves, although individual dose monitoring using TLD badges had been implemented. The available lead aprons also require specification verification because they were recorded as having a thickness of 0.2 mm Pb, whereas the recommended minimum standard is 0.25 mm Pb. The physical shielding of the examination room had met the applicable technical requirements. This study concludes that the provision of standardized PPE and the improvement of radiation protection competencies through regular training are necessary to support the implementation of the radiation optimization principle of As Low As Reasonably Achievable (ALARA).
Downloads
References
Agnesia, S., Sobar, S., & Saputra, F. (2025). Evaluasi Penerapan Standar K3 di Unit Radiologi RS Karya Medika I Tahun 2025. Jurnal Kesehatan Masyarakat Indonesia (JKMI), 2(4), 216–225. https://doi.org/10.62017/jkmi.v2i4.4833
AR, B. M., Hidayanto, E., & Richardina, V. (2018). Analisis Pengaruh Dosis Radiasi Eksternal Akumulasi Dosis yang Diterima Petugas Radiasi di Ruang Penyinaran Radioterapi RSUP Dr. Hasan Sadikin Bandung. Youngster Physics Journal, 7(2), 108–116.
Badan Pengawas Tenaga Nuklir. (2020). Peraturan Badan Pengawas Tenaga Nuklir Republik Indonesia Nomor 4 Tahun 2020 tentang Keselamatan Radiasi pada Penggunaan Pesawat Sinar-X dalam Radiologi Diagnostik dan Intervensional. Badan Pengawas Tenaga Nuklir Republik Indonesia.
Dianasari, T., & Koesyanto, H. (2017). Penerapan Manajemen Keselamatan Radiasi di Instalasi Radiologi Rumah Sakit. Unnes Journal of Public Health, 6(3), 174–183. https://doi.org/10.15294/ujph.v6i3.12690
Hidayat, H. H., Milvita, D., & Kurnia, I. (2020). Pengamatan Efek Radiasi melalui Pembentukan Foci γH2AX pada Sel Limfosit Radiografer. Jurnal Ilmu Fisika, 12(1), 1–5. https://doi.org/10.25077/jif.12.1.1-5.2020
Hiswara, E. (2020). Dosis Radiasi Pekerja dan Pasien pada Prosedur Intervensi di RSUP Dr. M. Djamil, Padang. Jurnal Kesehatan Andalas, 9(1), 39–47. https://doi.org/10.25077/jka.v9i1.1182
Mareta, S. (2023). Analisis Penerapan Keselamatan Radiasi pada Radiografer di Instalasi Radiologi RSU Mayjen H. A. Thalib Kerinci. Jurnal Kesehatan Medika Saintika, 14(1), 10–16. https://doi.org/10.30633/jkms.v14i1.1736
Misah, A., & Diartama, A. A. (2025). Analisis pengulangan (repeat) eksposure pada modalitas Digital Radiography (DR) di Rumah Sakit Daerah (RSD) Mangusada Badung. Jurnal Surya Medika, 11(2), 99–105. https://doi.org/10.33084/jsm.v11i2.7716
Muqmiroh, L., Praptono, S. I., Rusmanto, R., Latifah, R., & Sensusiati, A. D. (2018). The radiation dose profile in pediatric interventional cardiology to estimate the stochastic effect risk: Preliminary study. Journal of Vocational Health Studies, 1(3), 107–112. https://doi.org/10.20473/jvhs.V1.I3.2018.107-112
Sahfira, M. P., Milvita, D., & Hiswara, E. (2024). Pengujian Efektivitas Perisai Radiasi dan Evaluasi Penerapan Proteksi Radiasi di Instalasi Radiologi RSUD Prof. Dr. MA Hanafiah SM Batusangkar. Jurnal Fisika Unand, 13(2), 190–196. https://doi.org/10.25077/jfu.13.2.190-196.2024
Syaifudin, M. (2023). Biologi Radiasi: Dasar-Dasar dan Aplikasi. Badan Riset dan Inovasi Nasional. https://doi.org/10.55981/brin.563
Voss, S. D., Greer, M.-L. C., Doria, A. S., Shkumat, N. A., Akbari, E., Brodeur, G. M., & States, L. J. (2025). Radiation concepts and considerations for pediatric cancer predisposition syndrome surveillance: A report from the 2023 AACR Childhood Cancer Predisposition Workshop. Clinical Cancer Research, 31(17), 3638–3643. https://doi.org/10.1158/1078-0432.CCR-25-0597
Wijaya, S. S., Mukmin, A., & Nasokha, I. M. M. (2025). Penerapan Manajemen Radiasi dalam Aspek Peralatan Radiasi di RS TK III Dr. Soetarto. PREPOTIF: Jurnal Kesehatan Masyarakat, 9(2), 3808–3814. https://doi.org/10.31004/prepotif.v9i2.46761
Wulan, N., Manik, J. W., & Hakim, L. (2025). Analisis Desain Dinding Penahan Radiasi Ruang Radiografi Umum pada Salah Satu Rumah Sakit di Kota Palangka Raya. Magnetic: Research Journal of Physics and It’s Application, 5(1), 385–396. https://doi.org/10.59632/magnetic.v5i1.486
Yani, I., Pratiwi, A. D., & Yunawati, I. (2021). Studi Deskriptif Proteksi Radiasi dan Penerapannya di Instalasi Radiologi Rumah Sakit. HIGEIA (Journal of Public Health Research and Development, 5(3), 409–420. https://doi.org/10.15294/higeia.v5i3.41346
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Zulkifli Tri Darmawan, Muh Rusli, Herlinda Mahdania Harun, Sitti Normawati, Indah Musdalifah, Melinda

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.










